The plant must have four distinct sections that demonstrate three principles of turbulence, residence time and temperature retention. The regulated sections may include but not limited to: 
1. Overall plant layout 
2. Feed chamber/charging 
3. Primary combustion chamber 
4. Particulate scrubbers 
5. Acid gas scrubbers. 
6. The stack/chimney. 
7. Minimum capacity of primary chamber = 0.18 cubic metres 
8. Burn rate (rate of waste incineration) = a least 20 kg per hour 
9. Should have a full width counterbalance loading door allowing easy access to the main chamber for loading and removing ash. 
Supply, Installation and Commissioning of An Incinerator in Eastern Hydros [ Page 28 

2.2 Feeding and Charging 
Controlled hygienic mechanical feeding that does not negatively influence the air temperature in the primary and secondary chambers of the incinerator shall be used. 
2.3 Primary Combustion Chamber. 

a) This chamber should be equipped with burners that use low sulphur fuel. 
b) The chamber should ensure a minimum exit temperature of 850 degrees centigrade. 

2.4 Secondary Combustion Chamber (After burner) 

a) Should be fitted with burners that use low sulphur fuel. 
b) Ensure secondary air supply is controlled. 
c) Ensure residence time is not less than two seconds. 
d) Ensure that the gas temperature as measured against the inside wall in the secondary chamber and not in the flame zone is not less than 1100 degrees centigrade. 
e) Ensure the emitted oxygen content of the emitted gases is not less than 11% 
f) Ensure both primary and secondary combustion temperatures are maintained until all waste is completely combusted.